{
  "openapi": "3.0.0",
  "info": {
    "title": "SONET-MIB MIB API",
    "version": "1.0.0",
    "description": "The MIB module to describe SONET/SDH interface objects.\n    \n    Copyright (C) The Internet Society (2003).  This version\n    of this MIB module is part of RFC 3592;  see the RFC\n    itself for full legal notices.\n\n⚠️ **IMPORTANT - MIB DATA ACCESS**:\nThis YANG model exists for SMIv2-to-YANG translation purposes, but MIB data on IOS-XE devices is primarily accessed via **SNMP protocol**, not RESTCONF.\n\n**RESTCONF Limitation**: Many MIB paths may return 404 errors via RESTCONF `/data` endpoints because the device exposes MIB data through SNMP, not the YANG datastore.\n\n**Recommended Access Methods**:\n- Use SNMP (v2c/v3) to query MIB data directly\n- Use NETCONF `<get>` operations for devices supporting YANG-modeled MIB access\n- Check device capabilities: some newer IOS-XE versions may support limited RESTCONF access to specific MIBs\n\n**YANG Model Purpose**: These YANG models define the structure of SNMP MIBs in YANG format for tooling compatibility, but do not guarantee RESTCONF data availability.\n\n\n**📊 YANG Tree:** [View SONET-MIB structure](https://jeremycohoe.github.io/cisco-ios-xe-openapi-swagger/yang-trees/SONET-MIB.html)",
    "contact": {
      "name": "Cisco DevNet",
      "url": "https://developer.cisco.com"
    },
    "x-yang-module": "SONET-MIB",
    "x-model-type": "mib"
  },
  "servers": [
    {
      "url": "https://{device}/restconf",
      "description": "RESTCONF server",
      "variables": {
        "device": {
          "default": "10.1.1.1",
          "description": "Device hostname or IP address"
        }
      }
    }
  ],
  "paths": {
    "/data/SONET-MIB:sonetMedium": {
      "get": {
        "summary": "Get sonetMedium data",
        "description": "Retrieve sonetMedium operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "sonetMedium",
                  "properties": {
                    "sonetSESthresholdSet": {
                      "type": "string",
                      "description": "An enumerated integer indicating which\n          recognized set of SES thresholds that\n          the agent uses for determining severely\n          errored seconds and unavailable time.\n          \n          other(1)\n            None of the following.\n          \n          bellcore1991(2)\n            Bellcore TR-NWT-000253, 1991 [TR253], or\n            ANSI T1M1.3/93-005R2, 1993 [T1M1.3].\n            See also Appendix B.\n          \n          ansi1993(3)\n            ANSI T1.231, 1993 [T1.231a], or\n            Bellcore GR-253-CORE, Issue 2, 1995 [GR253]\n          \n          itu1995(4)\n            ITU Recommendation G.826, 1995 [G.826]\n          \n          ansi1997(5)\n            ANSI T1.231, 1997 [T1.231b]\n          \n          If a manager changes the value of this\n          object then the SES statistics collected\n          prior to this change must be invalidated."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMedium": {
                    "sonetSESthresholdSet": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMedium",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetMedium",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetMediumTable": {
      "get": {
        "summary": "Get sonetMediumTable data",
        "description": "Retrieve sonetMediumTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Medium table.",
                  "properties": {
                    "sonetMediumEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Medium table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetMediumType": {
                            "type": "string",
                            "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface."
                          },
                          "sonetMediumTimeElapsed": {
                            "type": "integer",
                            "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetMediumValidIntervals": {
                            "type": "integer",
                            "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetMediumLineCoding": {
                            "type": "string",
                            "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals."
                          },
                          "sonetMediumLineType": {
                            "type": "string",
                            "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values."
                          },
                          "sonetMediumCircuitIdentifier": {
                            "type": "string",
                            "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                            "x-yang-type": "snmpv2-tc:DisplayString"
                          },
                          "sonetMediumInvalidIntervals": {
                            "type": "integer",
                            "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetMediumLoopbackConfig": {
                            "type": "string",
                            "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMediumTable": {
                    "sonetMediumEntry": [
                      {
                        "ifIndex": "1",
                        "sonetMediumType": "ethernetCsmacd(6)",
                        "sonetMediumTimeElapsed": -2147483648,
                        "sonetMediumValidIntervals": -2147483648,
                        "sonetMediumLineCoding": "example-string",
                        "sonetMediumLineType": "ethernetCsmacd(6)",
                        "sonetMediumCircuitIdentifier": "example-string",
                        "sonetMediumInvalidIntervals": -2147483648,
                        "sonetMediumLoopbackConfig": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetMediumType": "ethernetCsmacd(6)",
                        "sonetMediumTimeElapsed": -2147483648,
                        "sonetMediumValidIntervals": -2147483648,
                        "sonetMediumLineCoding": "example-string",
                        "sonetMediumLineType": "ethernetCsmacd(6)",
                        "sonetMediumCircuitIdentifier": "example-string",
                        "sonetMediumInvalidIntervals": -2147483648,
                        "sonetMediumLoopbackConfig": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetMediumType": "ethernetCsmacd(6)",
                        "sonetMediumTimeElapsed": -2147483648,
                        "sonetMediumValidIntervals": -2147483648,
                        "sonetMediumLineCoding": "example-string",
                        "sonetMediumLineType": "ethernetCsmacd(6)",
                        "sonetMediumCircuitIdentifier": "example-string",
                        "sonetMediumInvalidIntervals": -2147483648,
                        "sonetMediumLoopbackConfig": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMediumTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetMediumTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetMediumTable/sonetMediumEntry": {
      "get": {
        "summary": "Get sonetMediumEntry list",
        "description": "Retrieve list of sonetMediumEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Medium table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetMediumType": {
                        "type": "string",
                        "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface."
                      },
                      "sonetMediumTimeElapsed": {
                        "type": "integer",
                        "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumValidIntervals": {
                        "type": "integer",
                        "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumLineCoding": {
                        "type": "string",
                        "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals."
                      },
                      "sonetMediumLineType": {
                        "type": "string",
                        "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values."
                      },
                      "sonetMediumCircuitIdentifier": {
                        "type": "string",
                        "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                        "x-yang-type": "snmpv2-tc:DisplayString"
                      },
                      "sonetMediumInvalidIntervals": {
                        "type": "integer",
                        "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumLoopbackConfig": {
                        "type": "string",
                        "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMediumEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetMediumType": "ethernetCsmacd(6)",
                      "sonetMediumTimeElapsed": -2147483648,
                      "sonetMediumValidIntervals": -2147483648,
                      "sonetMediumLineCoding": "example-string",
                      "sonetMediumLineType": "ethernetCsmacd(6)",
                      "sonetMediumCircuitIdentifier": "example-string",
                      "sonetMediumInvalidIntervals": -2147483648,
                      "sonetMediumLoopbackConfig": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMediumEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetMediumTable/sonetMediumEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetMediumTable/sonetMediumEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetMediumEntry entry",
        "description": "Retrieve specific sonetMediumEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetMediumType": {
                      "type": "string",
                      "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface."
                    },
                    "sonetMediumTimeElapsed": {
                      "type": "integer",
                      "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumValidIntervals": {
                      "type": "integer",
                      "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumLineCoding": {
                      "type": "string",
                      "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals."
                    },
                    "sonetMediumLineType": {
                      "type": "string",
                      "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values."
                    },
                    "sonetMediumCircuitIdentifier": {
                      "type": "string",
                      "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                      "x-yang-type": "snmpv2-tc:DisplayString"
                    },
                    "sonetMediumInvalidIntervals": {
                      "type": "integer",
                      "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumLoopbackConfig": {
                      "type": "string",
                      "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMediumEntry": {
                    "ifIndex": "example-string",
                    "sonetMediumType": "ethernetCsmacd(6)",
                    "sonetMediumTimeElapsed": -2147483648,
                    "sonetMediumValidIntervals": -2147483648,
                    "sonetMediumLineCoding": "example-string",
                    "sonetMediumLineType": "ethernetCsmacd(6)",
                    "sonetMediumCircuitIdentifier": "example-string",
                    "sonetMediumInvalidIntervals": -2147483648,
                    "sonetMediumLoopbackConfig": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMediumEntry-2"
      },
      "x-yang-path": "/sonetMediumTable/sonetMediumEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetSectionCurrentTable": {
      "get": {
        "summary": "Get sonetSectionCurrentTable data",
        "description": "Retrieve sonetSectionCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Section Current table.",
                  "properties": {
                    "sonetSectionCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Section Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetSectionCurrentStatus": {
                            "type": "integer",
                            "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetSectionCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetSectionCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetSectionCurrentSEFSs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetSectionCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionCurrentTable": {
                    "sonetSectionCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetSectionCurrentStatus": -2147483648,
                        "sonetSectionCurrentESs": "example-string",
                        "sonetSectionCurrentSESs": "example-string",
                        "sonetSectionCurrentSEFSs": "example-string",
                        "sonetSectionCurrentCVs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetSectionCurrentStatus": -2147483648,
                        "sonetSectionCurrentESs": "example-string",
                        "sonetSectionCurrentSESs": "example-string",
                        "sonetSectionCurrentSEFSs": "example-string",
                        "sonetSectionCurrentCVs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetSectionCurrentStatus": -2147483648,
                        "sonetSectionCurrentESs": "example-string",
                        "sonetSectionCurrentSESs": "example-string",
                        "sonetSectionCurrentSEFSs": "example-string",
                        "sonetSectionCurrentCVs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetSectionCurrentTable/sonetSectionCurrentEntry": {
      "get": {
        "summary": "Get sonetSectionCurrentEntry list",
        "description": "Retrieve list of sonetSectionCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Section Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetSectionCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetSectionCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentSEFSs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetSectionCurrentStatus": -2147483648,
                      "sonetSectionCurrentESs": "example-string",
                      "sonetSectionCurrentSESs": "example-string",
                      "sonetSectionCurrentSEFSs": "example-string",
                      "sonetSectionCurrentCVs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionCurrentTable/sonetSectionCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetSectionCurrentTable/sonetSectionCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetSectionCurrentEntry entry",
        "description": "Retrieve specific sonetSectionCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetSectionCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetSectionCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetSectionCurrentStatus": -2147483648,
                    "sonetSectionCurrentESs": "example-string",
                    "sonetSectionCurrentSESs": "example-string",
                    "sonetSectionCurrentSEFSs": "example-string",
                    "sonetSectionCurrentCVs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionCurrentEntry-2"
      },
      "x-yang-path": "/sonetSectionCurrentTable/sonetSectionCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetSectionIntervalTable": {
      "get": {
        "summary": "Get sonetSectionIntervalTable data",
        "description": "Retrieve sonetSectionIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Section Interval table.",
                  "properties": {
                    "sonetSectionIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Section Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetSectionIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetSectionIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetSectionIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetSectionIntervalSEFSs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetSectionIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetSectionIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionIntervalTable": {
                    "sonetSectionIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetSectionIntervalNumber": -2147483648,
                        "sonetSectionIntervalESs": "example-string",
                        "sonetSectionIntervalSESs": "example-string",
                        "sonetSectionIntervalSEFSs": "example-string",
                        "sonetSectionIntervalCVs": "example-string",
                        "sonetSectionIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetSectionIntervalNumber": -2147483648,
                        "sonetSectionIntervalESs": "example-string",
                        "sonetSectionIntervalSESs": "example-string",
                        "sonetSectionIntervalSEFSs": "example-string",
                        "sonetSectionIntervalCVs": "example-string",
                        "sonetSectionIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetSectionIntervalNumber": -2147483648,
                        "sonetSectionIntervalESs": "example-string",
                        "sonetSectionIntervalSESs": "example-string",
                        "sonetSectionIntervalSEFSs": "example-string",
                        "sonetSectionIntervalCVs": "example-string",
                        "sonetSectionIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetSectionIntervalTable/sonetSectionIntervalEntry": {
      "get": {
        "summary": "Get sonetSectionIntervalEntry list",
        "description": "Retrieve list of sonetSectionIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Section Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetSectionIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetSectionIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalSEFSs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetSectionIntervalNumber": -2147483648,
                      "sonetSectionIntervalESs": "example-string",
                      "sonetSectionIntervalSESs": "example-string",
                      "sonetSectionIntervalSEFSs": "example-string",
                      "sonetSectionIntervalCVs": "example-string",
                      "sonetSectionIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionIntervalTable/sonetSectionIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineCurrentTable": {
      "get": {
        "summary": "Get sonetLineCurrentTable data",
        "description": "Retrieve sonetLineCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Line Current table.",
                  "properties": {
                    "sonetLineCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Line Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetLineCurrentStatus": {
                            "type": "integer",
                            "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetLineCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetLineCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetLineCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetLineCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineCurrentTable": {
                    "sonetLineCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetLineCurrentStatus": -2147483648,
                        "sonetLineCurrentESs": "example-string",
                        "sonetLineCurrentSESs": "example-string",
                        "sonetLineCurrentCVs": "example-string",
                        "sonetLineCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetLineCurrentStatus": -2147483648,
                        "sonetLineCurrentESs": "example-string",
                        "sonetLineCurrentSESs": "example-string",
                        "sonetLineCurrentCVs": "example-string",
                        "sonetLineCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetLineCurrentStatus": -2147483648,
                        "sonetLineCurrentESs": "example-string",
                        "sonetLineCurrentSESs": "example-string",
                        "sonetLineCurrentCVs": "example-string",
                        "sonetLineCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineCurrentTable/sonetLineCurrentEntry": {
      "get": {
        "summary": "Get sonetLineCurrentEntry list",
        "description": "Retrieve list of sonetLineCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Line Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetLineCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetLineCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetLineCurrentStatus": -2147483648,
                      "sonetLineCurrentESs": "example-string",
                      "sonetLineCurrentSESs": "example-string",
                      "sonetLineCurrentCVs": "example-string",
                      "sonetLineCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineCurrentTable/sonetLineCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineCurrentTable/sonetLineCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetLineCurrentEntry entry",
        "description": "Retrieve specific sonetLineCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetLineCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetLineCurrentStatus": -2147483648,
                    "sonetLineCurrentESs": "example-string",
                    "sonetLineCurrentSESs": "example-string",
                    "sonetLineCurrentCVs": "example-string",
                    "sonetLineCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineCurrentEntry-2"
      },
      "x-yang-path": "/sonetLineCurrentTable/sonetLineCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetLineIntervalTable": {
      "get": {
        "summary": "Get sonetLineIntervalTable data",
        "description": "Retrieve sonetLineIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Line Interval table.",
                  "properties": {
                    "sonetLineIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Line Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetLineIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetLineIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetLineIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetLineIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetLineIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetLineIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineIntervalTable": {
                    "sonetLineIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetLineIntervalNumber": -2147483648,
                        "sonetLineIntervalESs": "example-string",
                        "sonetLineIntervalSESs": "example-string",
                        "sonetLineIntervalCVs": "example-string",
                        "sonetLineIntervalUASs": "example-string",
                        "sonetLineIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetLineIntervalNumber": -2147483648,
                        "sonetLineIntervalESs": "example-string",
                        "sonetLineIntervalSESs": "example-string",
                        "sonetLineIntervalCVs": "example-string",
                        "sonetLineIntervalUASs": "example-string",
                        "sonetLineIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetLineIntervalNumber": -2147483648,
                        "sonetLineIntervalESs": "example-string",
                        "sonetLineIntervalSESs": "example-string",
                        "sonetLineIntervalCVs": "example-string",
                        "sonetLineIntervalUASs": "example-string",
                        "sonetLineIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineIntervalTable/sonetLineIntervalEntry": {
      "get": {
        "summary": "Get sonetLineIntervalEntry list",
        "description": "Retrieve list of sonetLineIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Line Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetLineIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetLineIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetLineIntervalNumber": -2147483648,
                      "sonetLineIntervalESs": "example-string",
                      "sonetLineIntervalSESs": "example-string",
                      "sonetLineIntervalCVs": "example-string",
                      "sonetLineIntervalUASs": "example-string",
                      "sonetLineIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineIntervalTable/sonetLineIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineCurrentTable": {
      "get": {
        "summary": "Get sonetFarEndLineCurrentTable data",
        "description": "Retrieve sonetFarEndLineCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End Line Current table.",
                  "properties": {
                    "sonetFarEndLineCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far End Line Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndLineCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndLineCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndLineCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndLineCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineCurrentTable": {
                    "sonetFarEndLineCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndLineCurrentESs": "example-string",
                        "sonetFarEndLineCurrentSESs": "example-string",
                        "sonetFarEndLineCurrentCVs": "example-string",
                        "sonetFarEndLineCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndLineCurrentESs": "example-string",
                        "sonetFarEndLineCurrentSESs": "example-string",
                        "sonetFarEndLineCurrentCVs": "example-string",
                        "sonetFarEndLineCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndLineCurrentESs": "example-string",
                        "sonetFarEndLineCurrentSESs": "example-string",
                        "sonetFarEndLineCurrentCVs": "example-string",
                        "sonetFarEndLineCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineCurrentTable/sonetFarEndLineCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndLineCurrentEntry list",
        "description": "Retrieve list of sonetFarEndLineCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End Line Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndLineCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndLineCurrentESs": "example-string",
                      "sonetFarEndLineCurrentSESs": "example-string",
                      "sonetFarEndLineCurrentCVs": "example-string",
                      "sonetFarEndLineCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineCurrentTable/sonetFarEndLineCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineCurrentTable/sonetFarEndLineCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndLineCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndLineCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndLineCurrentESs": "example-string",
                    "sonetFarEndLineCurrentSESs": "example-string",
                    "sonetFarEndLineCurrentCVs": "example-string",
                    "sonetFarEndLineCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineCurrentEntry-2"
      },
      "x-yang-path": "/sonetFarEndLineCurrentTable/sonetFarEndLineCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndLineIntervalTable": {
      "get": {
        "summary": "Get sonetFarEndLineIntervalTable data",
        "description": "Retrieve sonetFarEndLineIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End Line Interval table.",
                  "properties": {
                    "sonetFarEndLineIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndLineIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetFarEndLineIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndLineIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndLineIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndLineIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndLineIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineIntervalTable": {
                    "sonetFarEndLineIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndLineIntervalNumber": -2147483648,
                        "sonetFarEndLineIntervalESs": "example-string",
                        "sonetFarEndLineIntervalSESs": "example-string",
                        "sonetFarEndLineIntervalCVs": "example-string",
                        "sonetFarEndLineIntervalUASs": "example-string",
                        "sonetFarEndLineIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndLineIntervalNumber": -2147483648,
                        "sonetFarEndLineIntervalESs": "example-string",
                        "sonetFarEndLineIntervalSESs": "example-string",
                        "sonetFarEndLineIntervalCVs": "example-string",
                        "sonetFarEndLineIntervalUASs": "example-string",
                        "sonetFarEndLineIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndLineIntervalNumber": -2147483648,
                        "sonetFarEndLineIntervalESs": "example-string",
                        "sonetFarEndLineIntervalSESs": "example-string",
                        "sonetFarEndLineIntervalCVs": "example-string",
                        "sonetFarEndLineIntervalUASs": "example-string",
                        "sonetFarEndLineIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineIntervalTable/sonetFarEndLineIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndLineIntervalEntry list",
        "description": "Retrieve list of sonetFarEndLineIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndLineIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndLineIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndLineIntervalNumber": -2147483648,
                      "sonetFarEndLineIntervalESs": "example-string",
                      "sonetFarEndLineIntervalSESs": "example-string",
                      "sonetFarEndLineIntervalCVs": "example-string",
                      "sonetFarEndLineIntervalUASs": "example-string",
                      "sonetFarEndLineIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineIntervalTable/sonetFarEndLineIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathCurrentTable": {
      "get": {
        "summary": "Get sonetPathCurrentTable data",
        "description": "Retrieve sonetPathCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Path Current table.",
                  "properties": {
                    "sonetPathCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Path Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetPathCurrentWidth": {
                            "type": "string",
                            "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
                          },
                          "sonetPathCurrentStatus": {
                            "type": "integer",
                            "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetPathCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetPathCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetPathCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetPathCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathCurrentTable": {
                    "sonetPathCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetPathCurrentWidth": "example-string",
                        "sonetPathCurrentStatus": -2147483648,
                        "sonetPathCurrentESs": "example-string",
                        "sonetPathCurrentSESs": "example-string",
                        "sonetPathCurrentCVs": "example-string",
                        "sonetPathCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetPathCurrentWidth": "example-string",
                        "sonetPathCurrentStatus": -2147483648,
                        "sonetPathCurrentESs": "example-string",
                        "sonetPathCurrentSESs": "example-string",
                        "sonetPathCurrentCVs": "example-string",
                        "sonetPathCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetPathCurrentWidth": "example-string",
                        "sonetPathCurrentStatus": -2147483648,
                        "sonetPathCurrentESs": "example-string",
                        "sonetPathCurrentSESs": "example-string",
                        "sonetPathCurrentCVs": "example-string",
                        "sonetPathCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathCurrentTable/sonetPathCurrentEntry": {
      "get": {
        "summary": "Get sonetPathCurrentEntry list",
        "description": "Retrieve list of sonetPathCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Path Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetPathCurrentWidth": {
                        "type": "string",
                        "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
                      },
                      "sonetPathCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetPathCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetPathCurrentWidth": "example-string",
                      "sonetPathCurrentStatus": -2147483648,
                      "sonetPathCurrentESs": "example-string",
                      "sonetPathCurrentSESs": "example-string",
                      "sonetPathCurrentCVs": "example-string",
                      "sonetPathCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathCurrentTable/sonetPathCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathCurrentTable/sonetPathCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetPathCurrentEntry entry",
        "description": "Retrieve specific sonetPathCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetPathCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
                    },
                    "sonetPathCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetPathCurrentWidth": "example-string",
                    "sonetPathCurrentStatus": -2147483648,
                    "sonetPathCurrentESs": "example-string",
                    "sonetPathCurrentSESs": "example-string",
                    "sonetPathCurrentCVs": "example-string",
                    "sonetPathCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathCurrentEntry-2"
      },
      "x-yang-path": "/sonetPathCurrentTable/sonetPathCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetPathIntervalTable": {
      "get": {
        "summary": "Get sonetPathIntervalTable data",
        "description": "Retrieve sonetPathIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Path Interval table.",
                  "properties": {
                    "sonetPathIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Path Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetPathIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetPathIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetPathIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetPathIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetPathIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetPathIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathIntervalTable": {
                    "sonetPathIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetPathIntervalNumber": -2147483648,
                        "sonetPathIntervalESs": "example-string",
                        "sonetPathIntervalSESs": "example-string",
                        "sonetPathIntervalCVs": "example-string",
                        "sonetPathIntervalUASs": "example-string",
                        "sonetPathIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetPathIntervalNumber": -2147483648,
                        "sonetPathIntervalESs": "example-string",
                        "sonetPathIntervalSESs": "example-string",
                        "sonetPathIntervalCVs": "example-string",
                        "sonetPathIntervalUASs": "example-string",
                        "sonetPathIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetPathIntervalNumber": -2147483648,
                        "sonetPathIntervalESs": "example-string",
                        "sonetPathIntervalSESs": "example-string",
                        "sonetPathIntervalCVs": "example-string",
                        "sonetPathIntervalUASs": "example-string",
                        "sonetPathIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathIntervalTable/sonetPathIntervalEntry": {
      "get": {
        "summary": "Get sonetPathIntervalEntry list",
        "description": "Retrieve list of sonetPathIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Path Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetPathIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetPathIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetPathIntervalNumber": -2147483648,
                      "sonetPathIntervalESs": "example-string",
                      "sonetPathIntervalSESs": "example-string",
                      "sonetPathIntervalCVs": "example-string",
                      "sonetPathIntervalUASs": "example-string",
                      "sonetPathIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathIntervalTable/sonetPathIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathCurrentTable": {
      "get": {
        "summary": "Get sonetFarEndPathCurrentTable data",
        "description": "Retrieve sonetFarEndPathCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End Path Current table.",
                  "properties": {
                    "sonetFarEndPathCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far End Path Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndPathCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndPathCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndPathCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndPathCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathCurrentTable": {
                    "sonetFarEndPathCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndPathCurrentESs": "example-string",
                        "sonetFarEndPathCurrentSESs": "example-string",
                        "sonetFarEndPathCurrentCVs": "example-string",
                        "sonetFarEndPathCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndPathCurrentESs": "example-string",
                        "sonetFarEndPathCurrentSESs": "example-string",
                        "sonetFarEndPathCurrentCVs": "example-string",
                        "sonetFarEndPathCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndPathCurrentESs": "example-string",
                        "sonetFarEndPathCurrentSESs": "example-string",
                        "sonetFarEndPathCurrentCVs": "example-string",
                        "sonetFarEndPathCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathCurrentTable/sonetFarEndPathCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndPathCurrentEntry list",
        "description": "Retrieve list of sonetFarEndPathCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End Path Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndPathCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndPathCurrentESs": "example-string",
                      "sonetFarEndPathCurrentSESs": "example-string",
                      "sonetFarEndPathCurrentCVs": "example-string",
                      "sonetFarEndPathCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathCurrentTable/sonetFarEndPathCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathCurrentTable/sonetFarEndPathCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndPathCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndPathCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndPathCurrentESs": "example-string",
                    "sonetFarEndPathCurrentSESs": "example-string",
                    "sonetFarEndPathCurrentCVs": "example-string",
                    "sonetFarEndPathCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathCurrentEntry-2"
      },
      "x-yang-path": "/sonetFarEndPathCurrentTable/sonetFarEndPathCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndPathIntervalTable": {
      "get": {
        "summary": "Get sonetFarEndPathIntervalTable data",
        "description": "Retrieve sonetFarEndPathIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End Path Interval table.",
                  "properties": {
                    "sonetFarEndPathIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndPathIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetFarEndPathIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndPathIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndPathIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndPathIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndPathIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathIntervalTable": {
                    "sonetFarEndPathIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndPathIntervalNumber": -2147483648,
                        "sonetFarEndPathIntervalESs": "example-string",
                        "sonetFarEndPathIntervalSESs": "example-string",
                        "sonetFarEndPathIntervalCVs": "example-string",
                        "sonetFarEndPathIntervalUASs": "example-string",
                        "sonetFarEndPathIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndPathIntervalNumber": -2147483648,
                        "sonetFarEndPathIntervalESs": "example-string",
                        "sonetFarEndPathIntervalSESs": "example-string",
                        "sonetFarEndPathIntervalCVs": "example-string",
                        "sonetFarEndPathIntervalUASs": "example-string",
                        "sonetFarEndPathIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndPathIntervalNumber": -2147483648,
                        "sonetFarEndPathIntervalESs": "example-string",
                        "sonetFarEndPathIntervalSESs": "example-string",
                        "sonetFarEndPathIntervalCVs": "example-string",
                        "sonetFarEndPathIntervalUASs": "example-string",
                        "sonetFarEndPathIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathIntervalTable/sonetFarEndPathIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndPathIntervalEntry list",
        "description": "Retrieve list of sonetFarEndPathIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndPathIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndPathIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndPathIntervalNumber": -2147483648,
                      "sonetFarEndPathIntervalESs": "example-string",
                      "sonetFarEndPathIntervalSESs": "example-string",
                      "sonetFarEndPathIntervalCVs": "example-string",
                      "sonetFarEndPathIntervalUASs": "example-string",
                      "sonetFarEndPathIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathIntervalTable/sonetFarEndPathIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTCurrentTable": {
      "get": {
        "summary": "Get sonetVTCurrentTable data",
        "description": "Retrieve sonetVTCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH VT Current table.",
                  "properties": {
                    "sonetVTCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH VT Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetVTCurrentWidth": {
                            "type": "string",
                            "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
                          },
                          "sonetVTCurrentStatus": {
                            "type": "integer",
                            "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetVTCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetVTCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetVTCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetVTCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTCurrentTable": {
                    "sonetVTCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetVTCurrentWidth": "example-string",
                        "sonetVTCurrentStatus": -2147483648,
                        "sonetVTCurrentESs": "example-string",
                        "sonetVTCurrentSESs": "example-string",
                        "sonetVTCurrentCVs": "example-string",
                        "sonetVTCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetVTCurrentWidth": "example-string",
                        "sonetVTCurrentStatus": -2147483648,
                        "sonetVTCurrentESs": "example-string",
                        "sonetVTCurrentSESs": "example-string",
                        "sonetVTCurrentCVs": "example-string",
                        "sonetVTCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetVTCurrentWidth": "example-string",
                        "sonetVTCurrentStatus": -2147483648,
                        "sonetVTCurrentESs": "example-string",
                        "sonetVTCurrentSESs": "example-string",
                        "sonetVTCurrentCVs": "example-string",
                        "sonetVTCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTCurrentTable/sonetVTCurrentEntry": {
      "get": {
        "summary": "Get sonetVTCurrentEntry list",
        "description": "Retrieve list of sonetVTCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH VT Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetVTCurrentWidth": {
                        "type": "string",
                        "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
                      },
                      "sonetVTCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetVTCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetVTCurrentWidth": "example-string",
                      "sonetVTCurrentStatus": -2147483648,
                      "sonetVTCurrentESs": "example-string",
                      "sonetVTCurrentSESs": "example-string",
                      "sonetVTCurrentCVs": "example-string",
                      "sonetVTCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTCurrentTable/sonetVTCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTCurrentTable/sonetVTCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetVTCurrentEntry entry",
        "description": "Retrieve specific sonetVTCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetVTCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
                    },
                    "sonetVTCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetVTCurrentWidth": "example-string",
                    "sonetVTCurrentStatus": -2147483648,
                    "sonetVTCurrentESs": "example-string",
                    "sonetVTCurrentSESs": "example-string",
                    "sonetVTCurrentCVs": "example-string",
                    "sonetVTCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTCurrentEntry-2"
      },
      "x-yang-path": "/sonetVTCurrentTable/sonetVTCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetVTIntervalTable": {
      "get": {
        "summary": "Get sonetVTIntervalTable data",
        "description": "Retrieve sonetVTIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH VT Interval table.",
                  "properties": {
                    "sonetVTIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH VT Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetVTIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetVTIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetVTIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetVTIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetVTIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetVTIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTIntervalTable": {
                    "sonetVTIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetVTIntervalNumber": -2147483648,
                        "sonetVTIntervalESs": "example-string",
                        "sonetVTIntervalSESs": "example-string",
                        "sonetVTIntervalCVs": "example-string",
                        "sonetVTIntervalUASs": "example-string",
                        "sonetVTIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetVTIntervalNumber": -2147483648,
                        "sonetVTIntervalESs": "example-string",
                        "sonetVTIntervalSESs": "example-string",
                        "sonetVTIntervalCVs": "example-string",
                        "sonetVTIntervalUASs": "example-string",
                        "sonetVTIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetVTIntervalNumber": -2147483648,
                        "sonetVTIntervalESs": "example-string",
                        "sonetVTIntervalSESs": "example-string",
                        "sonetVTIntervalCVs": "example-string",
                        "sonetVTIntervalUASs": "example-string",
                        "sonetVTIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTIntervalTable/sonetVTIntervalEntry": {
      "get": {
        "summary": "Get sonetVTIntervalEntry list",
        "description": "Retrieve list of sonetVTIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH VT Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetVTIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetVTIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetVTIntervalNumber": -2147483648,
                      "sonetVTIntervalESs": "example-string",
                      "sonetVTIntervalSESs": "example-string",
                      "sonetVTIntervalCVs": "example-string",
                      "sonetVTIntervalUASs": "example-string",
                      "sonetVTIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTIntervalTable/sonetVTIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTCurrentTable": {
      "get": {
        "summary": "Get sonetFarEndVTCurrentTable data",
        "description": "Retrieve sonetFarEndVTCurrentTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End VT Current table.",
                  "properties": {
                    "sonetFarEndVTCurrentEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far End VT Current table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndVTCurrentESs": {
                            "type": "string",
                            "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndVTCurrentSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndVTCurrentCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          },
                          "sonetFarEndVTCurrentUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                            "x-yang-type": "perfhist-tc:PerfCurrentCount"
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTCurrentTable": {
                    "sonetFarEndVTCurrentEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndVTCurrentESs": "example-string",
                        "sonetFarEndVTCurrentSESs": "example-string",
                        "sonetFarEndVTCurrentCVs": "example-string",
                        "sonetFarEndVTCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndVTCurrentESs": "example-string",
                        "sonetFarEndVTCurrentSESs": "example-string",
                        "sonetFarEndVTCurrentCVs": "example-string",
                        "sonetFarEndVTCurrentUASs": "example-string"
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndVTCurrentESs": "example-string",
                        "sonetFarEndVTCurrentSESs": "example-string",
                        "sonetFarEndVTCurrentCVs": "example-string",
                        "sonetFarEndVTCurrentUASs": "example-string"
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTCurrentTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTCurrentTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTCurrentTable/sonetFarEndVTCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndVTCurrentEntry list",
        "description": "Retrieve list of sonetFarEndVTCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End VT Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndVTCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndVTCurrentESs": "example-string",
                      "sonetFarEndVTCurrentSESs": "example-string",
                      "sonetFarEndVTCurrentCVs": "example-string",
                      "sonetFarEndVTCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTCurrentEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTCurrentTable/sonetFarEndVTCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTCurrentTable/sonetFarEndVTCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndVTCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndVTCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndVTCurrentESs": "example-string",
                    "sonetFarEndVTCurrentSESs": "example-string",
                    "sonetFarEndVTCurrentCVs": "example-string",
                    "sonetFarEndVTCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTCurrentEntry-2"
      },
      "x-yang-path": "/sonetFarEndVTCurrentTable/sonetFarEndVTCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndVTIntervalTable": {
      "get": {
        "summary": "Get sonetFarEndVTIntervalTable data",
        "description": "Retrieve sonetFarEndVTIntervalTable operational data from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "description": "The SONET/SDH Far End VT Interval table.",
                  "properties": {
                    "sonetFarEndVTIntervalEntry": {
                      "type": "array",
                      "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
                      "items": {
                        "type": "object",
                        "properties": {
                          "ifIndex": {
                            "type": "string",
                            "description": "ifIndex",
                            "x-yang-type": "leafref"
                          },
                          "sonetFarEndVTIntervalNumber": {
                            "type": "integer",
                            "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                            "minimum": -2147483648,
                            "maximum": 2147483647
                          },
                          "sonetFarEndVTIntervalESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndVTIntervalSESs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndVTIntervalCVs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndVTIntervalUASs": {
                            "type": "string",
                            "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                            "x-yang-type": "perfhist-tc:PerfIntervalCount"
                          },
                          "sonetFarEndVTIntervalValidData": {
                            "type": "boolean",
                            "description": "This variable indicates if the data for this\n            interval is valid."
                          }
                        }
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTIntervalTable": {
                    "sonetFarEndVTIntervalEntry": [
                      {
                        "ifIndex": "1",
                        "sonetFarEndVTIntervalNumber": -2147483648,
                        "sonetFarEndVTIntervalESs": "example-string",
                        "sonetFarEndVTIntervalSESs": "example-string",
                        "sonetFarEndVTIntervalCVs": "example-string",
                        "sonetFarEndVTIntervalUASs": "example-string",
                        "sonetFarEndVTIntervalValidData": true
                      },
                      {
                        "ifIndex": "2",
                        "sonetFarEndVTIntervalNumber": -2147483648,
                        "sonetFarEndVTIntervalESs": "example-string",
                        "sonetFarEndVTIntervalSESs": "example-string",
                        "sonetFarEndVTIntervalCVs": "example-string",
                        "sonetFarEndVTIntervalUASs": "example-string",
                        "sonetFarEndVTIntervalValidData": true
                      },
                      {
                        "ifIndex": "3",
                        "sonetFarEndVTIntervalNumber": -2147483648,
                        "sonetFarEndVTIntervalESs": "example-string",
                        "sonetFarEndVTIntervalSESs": "example-string",
                        "sonetFarEndVTIntervalCVs": "example-string",
                        "sonetFarEndVTIntervalUASs": "example-string",
                        "sonetFarEndVTIntervalValidData": true
                      }
                    ]
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTIntervalTable",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTIntervalTable",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTIntervalTable/sonetFarEndVTIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndVTIntervalEntry list",
        "description": "Retrieve list of sonetFarEndVTIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndVTIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndVTIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndVTIntervalNumber": -2147483648,
                      "sonetFarEndVTIntervalESs": "example-string",
                      "sonetFarEndVTIntervalSESs": "example-string",
                      "sonetFarEndVTIntervalCVs": "example-string",
                      "sonetFarEndVTIntervalUASs": "example-string",
                      "sonetFarEndVTIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTIntervalEntry",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTIntervalTable/sonetFarEndVTIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetMediumEntry": {
      "get": {
        "summary": "Get sonetMediumEntry list",
        "description": "Retrieve list of sonetMediumEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Medium table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetMediumType": {
                        "type": "string",
                        "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface."
                      },
                      "sonetMediumTimeElapsed": {
                        "type": "integer",
                        "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumValidIntervals": {
                        "type": "integer",
                        "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumLineCoding": {
                        "type": "string",
                        "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals."
                      },
                      "sonetMediumLineType": {
                        "type": "string",
                        "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values."
                      },
                      "sonetMediumCircuitIdentifier": {
                        "type": "string",
                        "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                        "x-yang-type": "snmpv2-tc:DisplayString"
                      },
                      "sonetMediumInvalidIntervals": {
                        "type": "integer",
                        "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetMediumLoopbackConfig": {
                        "type": "string",
                        "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMediumEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetMediumType": "ethernetCsmacd(6)",
                      "sonetMediumTimeElapsed": -2147483648,
                      "sonetMediumValidIntervals": -2147483648,
                      "sonetMediumLineCoding": "example-string",
                      "sonetMediumLineType": "ethernetCsmacd(6)",
                      "sonetMediumCircuitIdentifier": "example-string",
                      "sonetMediumInvalidIntervals": -2147483648,
                      "sonetMediumLoopbackConfig": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMediumEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetMediumEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetMediumEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetMediumEntry entry",
        "description": "Retrieve specific sonetMediumEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetMediumType": {
                      "type": "string",
                      "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface."
                    },
                    "sonetMediumTimeElapsed": {
                      "type": "integer",
                      "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumValidIntervals": {
                      "type": "integer",
                      "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumLineCoding": {
                      "type": "string",
                      "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals."
                    },
                    "sonetMediumLineType": {
                      "type": "string",
                      "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values."
                    },
                    "sonetMediumCircuitIdentifier": {
                      "type": "string",
                      "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                      "x-yang-type": "snmpv2-tc:DisplayString"
                    },
                    "sonetMediumInvalidIntervals": {
                      "type": "integer",
                      "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetMediumLoopbackConfig": {
                      "type": "string",
                      "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetMediumEntry": {
                    "ifIndex": "example-string",
                    "sonetMediumType": "ethernetCsmacd(6)",
                    "sonetMediumTimeElapsed": -2147483648,
                    "sonetMediumValidIntervals": -2147483648,
                    "sonetMediumLineCoding": "example-string",
                    "sonetMediumLineType": "ethernetCsmacd(6)",
                    "sonetMediumCircuitIdentifier": "example-string",
                    "sonetMediumInvalidIntervals": -2147483648,
                    "sonetMediumLoopbackConfig": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetMediumEntry-4"
      },
      "x-yang-path": "/sonetMediumEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetSectionCurrentEntry": {
      "get": {
        "summary": "Get sonetSectionCurrentEntry list",
        "description": "Retrieve list of sonetSectionCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Section Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetSectionCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetSectionCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentSEFSs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetSectionCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetSectionCurrentStatus": -2147483648,
                      "sonetSectionCurrentESs": "example-string",
                      "sonetSectionCurrentSESs": "example-string",
                      "sonetSectionCurrentSEFSs": "example-string",
                      "sonetSectionCurrentCVs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetSectionCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetSectionCurrentEntry entry",
        "description": "Retrieve specific sonetSectionCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetSectionCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetSectionCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetSectionCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetSectionCurrentStatus": -2147483648,
                    "sonetSectionCurrentESs": "example-string",
                    "sonetSectionCurrentSESs": "example-string",
                    "sonetSectionCurrentSEFSs": "example-string",
                    "sonetSectionCurrentCVs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionCurrentEntry-4"
      },
      "x-yang-path": "/sonetSectionCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetSectionIntervalEntry": {
      "get": {
        "summary": "Get sonetSectionIntervalEntry list",
        "description": "Retrieve list of sonetSectionIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Section Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetSectionIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetSectionIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalSEFSs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetSectionIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetSectionIntervalNumber": -2147483648,
                      "sonetSectionIntervalESs": "example-string",
                      "sonetSectionIntervalSESs": "example-string",
                      "sonetSectionIntervalSEFSs": "example-string",
                      "sonetSectionIntervalCVs": "example-string",
                      "sonetSectionIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetSectionIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineCurrentEntry": {
      "get": {
        "summary": "Get sonetLineCurrentEntry list",
        "description": "Retrieve list of sonetLineCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Line Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetLineCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetLineCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetLineCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetLineCurrentStatus": -2147483648,
                      "sonetLineCurrentESs": "example-string",
                      "sonetLineCurrentSESs": "example-string",
                      "sonetLineCurrentCVs": "example-string",
                      "sonetLineCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetLineCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetLineCurrentEntry entry",
        "description": "Retrieve specific sonetLineCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetLineCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetLineCurrentStatus": -2147483648,
                    "sonetLineCurrentESs": "example-string",
                    "sonetLineCurrentSESs": "example-string",
                    "sonetLineCurrentCVs": "example-string",
                    "sonetLineCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineCurrentEntry-4"
      },
      "x-yang-path": "/sonetLineCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetLineIntervalEntry": {
      "get": {
        "summary": "Get sonetLineIntervalEntry list",
        "description": "Retrieve list of sonetLineIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Line Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetLineIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetLineIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetLineIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetLineIntervalNumber": -2147483648,
                      "sonetLineIntervalESs": "example-string",
                      "sonetLineIntervalSESs": "example-string",
                      "sonetLineIntervalCVs": "example-string",
                      "sonetLineIntervalUASs": "example-string",
                      "sonetLineIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetLineIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndLineCurrentEntry list",
        "description": "Retrieve list of sonetFarEndLineCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End Line Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndLineCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndLineCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndLineCurrentESs": "example-string",
                      "sonetFarEndLineCurrentSESs": "example-string",
                      "sonetFarEndLineCurrentCVs": "example-string",
                      "sonetFarEndLineCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndLineCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndLineCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndLineCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndLineCurrentESs": "example-string",
                    "sonetFarEndLineCurrentSESs": "example-string",
                    "sonetFarEndLineCurrentCVs": "example-string",
                    "sonetFarEndLineCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineCurrentEntry-4"
      },
      "x-yang-path": "/sonetFarEndLineCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndLineIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndLineIntervalEntry list",
        "description": "Retrieve list of sonetFarEndLineIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndLineIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndLineIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndLineIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndLineIntervalNumber": -2147483648,
                      "sonetFarEndLineIntervalESs": "example-string",
                      "sonetFarEndLineIntervalSESs": "example-string",
                      "sonetFarEndLineIntervalCVs": "example-string",
                      "sonetFarEndLineIntervalUASs": "example-string",
                      "sonetFarEndLineIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndLineIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathCurrentEntry": {
      "get": {
        "summary": "Get sonetPathCurrentEntry list",
        "description": "Retrieve list of sonetPathCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Path Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetPathCurrentWidth": {
                        "type": "string",
                        "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
                      },
                      "sonetPathCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetPathCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetPathCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetPathCurrentWidth": "example-string",
                      "sonetPathCurrentStatus": -2147483648,
                      "sonetPathCurrentESs": "example-string",
                      "sonetPathCurrentSESs": "example-string",
                      "sonetPathCurrentCVs": "example-string",
                      "sonetPathCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetPathCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetPathCurrentEntry entry",
        "description": "Retrieve specific sonetPathCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetPathCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256."
                    },
                    "sonetPathCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetPathCurrentWidth": "example-string",
                    "sonetPathCurrentStatus": -2147483648,
                    "sonetPathCurrentESs": "example-string",
                    "sonetPathCurrentSESs": "example-string",
                    "sonetPathCurrentCVs": "example-string",
                    "sonetPathCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathCurrentEntry-4"
      },
      "x-yang-path": "/sonetPathCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetPathIntervalEntry": {
      "get": {
        "summary": "Get sonetPathIntervalEntry list",
        "description": "Retrieve list of sonetPathIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Path Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetPathIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetPathIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetPathIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetPathIntervalNumber": -2147483648,
                      "sonetPathIntervalESs": "example-string",
                      "sonetPathIntervalSESs": "example-string",
                      "sonetPathIntervalCVs": "example-string",
                      "sonetPathIntervalUASs": "example-string",
                      "sonetPathIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetPathIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndPathCurrentEntry list",
        "description": "Retrieve list of sonetFarEndPathCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End Path Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndPathCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndPathCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndPathCurrentESs": "example-string",
                      "sonetFarEndPathCurrentSESs": "example-string",
                      "sonetFarEndPathCurrentCVs": "example-string",
                      "sonetFarEndPathCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndPathCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndPathCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndPathCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndPathCurrentESs": "example-string",
                    "sonetFarEndPathCurrentSESs": "example-string",
                    "sonetFarEndPathCurrentCVs": "example-string",
                    "sonetFarEndPathCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathCurrentEntry-4"
      },
      "x-yang-path": "/sonetFarEndPathCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndPathIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndPathIntervalEntry list",
        "description": "Retrieve list of sonetFarEndPathIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndPathIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndPathIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndPathIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndPathIntervalNumber": -2147483648,
                      "sonetFarEndPathIntervalESs": "example-string",
                      "sonetFarEndPathIntervalSESs": "example-string",
                      "sonetFarEndPathIntervalCVs": "example-string",
                      "sonetFarEndPathIntervalUASs": "example-string",
                      "sonetFarEndPathIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndPathIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTCurrentEntry": {
      "get": {
        "summary": "Get sonetVTCurrentEntry list",
        "description": "Retrieve list of sonetVTCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH VT Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetVTCurrentWidth": {
                        "type": "string",
                        "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
                      },
                      "sonetVTCurrentStatus": {
                        "type": "integer",
                        "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetVTCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetVTCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetVTCurrentWidth": "example-string",
                      "sonetVTCurrentStatus": -2147483648,
                      "sonetVTCurrentESs": "example-string",
                      "sonetVTCurrentSESs": "example-string",
                      "sonetVTCurrentCVs": "example-string",
                      "sonetVTCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetVTCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetVTCurrentEntry entry",
        "description": "Retrieve specific sonetVTCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetVTCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
                    },
                    "sonetVTCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetVTCurrentWidth": "example-string",
                    "sonetVTCurrentStatus": -2147483648,
                    "sonetVTCurrentESs": "example-string",
                    "sonetVTCurrentSESs": "example-string",
                    "sonetVTCurrentCVs": "example-string",
                    "sonetVTCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTCurrentEntry-4"
      },
      "x-yang-path": "/sonetVTCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetVTIntervalEntry": {
      "get": {
        "summary": "Get sonetVTIntervalEntry list",
        "description": "Retrieve list of sonetVTIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH VT Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetVTIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetVTIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetVTIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetVTIntervalNumber": -2147483648,
                      "sonetVTIntervalESs": "example-string",
                      "sonetVTIntervalSESs": "example-string",
                      "sonetVTIntervalCVs": "example-string",
                      "sonetVTIntervalUASs": "example-string",
                      "sonetVTIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetVTIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTCurrentEntry": {
      "get": {
        "summary": "Get sonetFarEndVTCurrentEntry list",
        "description": "Retrieve list of sonetFarEndVTCurrentEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far End VT Current table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndVTCurrentESs": {
                        "type": "string",
                        "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      },
                      "sonetFarEndVTCurrentUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                        "x-yang-type": "perfhist-tc:PerfCurrentCount"
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTCurrentEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndVTCurrentESs": "example-string",
                      "sonetFarEndVTCurrentSESs": "example-string",
                      "sonetFarEndVTCurrentCVs": "example-string",
                      "sonetFarEndVTCurrentUASs": "example-string"
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTCurrentEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTCurrentEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetFarEndVTCurrentEntry={ifIndex}": {
      "get": {
        "summary": "Get sonetFarEndVTCurrentEntry entry",
        "description": "Retrieve specific sonetFarEndVTCurrentEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            },
            "example": "1"
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    },
                    "sonetFarEndVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount"
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTCurrentEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndVTCurrentESs": "example-string",
                    "sonetFarEndVTCurrentSESs": "example-string",
                    "sonetFarEndVTCurrentCVs": "example-string",
                    "sonetFarEndVTCurrentUASs": "example-string"
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTCurrentEntry-4"
      },
      "x-yang-path": "/sonetFarEndVTCurrentEntry={ifIndex}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex"
      ]
    },
    "/data/SONET-MIB:sonetFarEndVTIntervalEntry": {
      "get": {
        "summary": "Get sonetFarEndVTIntervalEntry list",
        "description": "Retrieve list of sonetFarEndVTIntervalEntry entries from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "array",
                  "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
                  "items": {
                    "type": "object",
                    "properties": {
                      "ifIndex": {
                        "type": "string",
                        "description": "ifIndex",
                        "x-yang-type": "leafref"
                      },
                      "sonetFarEndVTIntervalNumber": {
                        "type": "integer",
                        "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                        "minimum": -2147483648,
                        "maximum": 2147483647
                      },
                      "sonetFarEndVTIntervalESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalSESs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalCVs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalUASs": {
                        "type": "string",
                        "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                        "x-yang-type": "perfhist-tc:PerfIntervalCount"
                      },
                      "sonetFarEndVTIntervalValidData": {
                        "type": "boolean",
                        "description": "This variable indicates if the data for this\n            interval is valid."
                      }
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTIntervalEntry": [
                    {
                      "ifIndex": "example-string",
                      "sonetFarEndVTIntervalNumber": -2147483648,
                      "sonetFarEndVTIntervalESs": "example-string",
                      "sonetFarEndVTIntervalSESs": "example-string",
                      "sonetFarEndVTIntervalCVs": "example-string",
                      "sonetFarEndVTIntervalUASs": "example-string",
                      "sonetFarEndVTIntervalValidData": true
                    }
                  ]
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTIntervalEntry-3",
        "parameters": [
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ]
      },
      "x-yang-path": "/sonetFarEndVTIntervalEntry",
      "x-restconf-kind": "container"
    },
    "/data/SONET-MIB:sonetSectionIntervalTable/sonetSectionIntervalEntry={ifIndex},{sonetSectionIntervalNumber}": {
      "get": {
        "summary": "Get sonetSectionIntervalEntry entry",
        "description": "Retrieve specific sonetSectionIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetSectionIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetSectionIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetSectionIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetSectionIntervalNumber": -2147483648,
                    "sonetSectionIntervalESs": "example-string",
                    "sonetSectionIntervalSESs": "example-string",
                    "sonetSectionIntervalSEFSs": "example-string",
                    "sonetSectionIntervalCVs": "example-string",
                    "sonetSectionIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionIntervalEntry-2"
      },
      "x-yang-path": "/sonetSectionIntervalTable/sonetSectionIntervalEntry={ifIndex sonetSectionIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetSectionIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetLineIntervalTable/sonetLineIntervalEntry={ifIndex},{sonetLineIntervalNumber}": {
      "get": {
        "summary": "Get sonetLineIntervalEntry entry",
        "description": "Retrieve specific sonetLineIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetLineIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetLineIntervalNumber": -2147483648,
                    "sonetLineIntervalESs": "example-string",
                    "sonetLineIntervalSESs": "example-string",
                    "sonetLineIntervalCVs": "example-string",
                    "sonetLineIntervalUASs": "example-string",
                    "sonetLineIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineIntervalEntry-2"
      },
      "x-yang-path": "/sonetLineIntervalTable/sonetLineIntervalEntry={ifIndex sonetLineIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetLineIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndLineIntervalTable/sonetFarEndLineIntervalEntry={ifIndex},{sonetFarEndLineIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndLineIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndLineIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndLineIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndLineIntervalNumber": -2147483648,
                    "sonetFarEndLineIntervalESs": "example-string",
                    "sonetFarEndLineIntervalSESs": "example-string",
                    "sonetFarEndLineIntervalCVs": "example-string",
                    "sonetFarEndLineIntervalUASs": "example-string",
                    "sonetFarEndLineIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineIntervalEntry-2"
      },
      "x-yang-path": "/sonetFarEndLineIntervalTable/sonetFarEndLineIntervalEntry={ifIndex sonetFarEndLineIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndLineIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetPathIntervalTable/sonetPathIntervalEntry={ifIndex},{sonetPathIntervalNumber}": {
      "get": {
        "summary": "Get sonetPathIntervalEntry entry",
        "description": "Retrieve specific sonetPathIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetPathIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetPathIntervalNumber": -2147483648,
                    "sonetPathIntervalESs": "example-string",
                    "sonetPathIntervalSESs": "example-string",
                    "sonetPathIntervalCVs": "example-string",
                    "sonetPathIntervalUASs": "example-string",
                    "sonetPathIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathIntervalEntry-2"
      },
      "x-yang-path": "/sonetPathIntervalTable/sonetPathIntervalEntry={ifIndex sonetPathIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetPathIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndPathIntervalTable/sonetFarEndPathIntervalEntry={ifIndex},{sonetFarEndPathIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndPathIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndPathIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndPathIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndPathIntervalNumber": -2147483648,
                    "sonetFarEndPathIntervalESs": "example-string",
                    "sonetFarEndPathIntervalSESs": "example-string",
                    "sonetFarEndPathIntervalCVs": "example-string",
                    "sonetFarEndPathIntervalUASs": "example-string",
                    "sonetFarEndPathIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathIntervalEntry-2"
      },
      "x-yang-path": "/sonetFarEndPathIntervalTable/sonetFarEndPathIntervalEntry={ifIndex sonetFarEndPathIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndPathIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetVTIntervalTable/sonetVTIntervalEntry={ifIndex},{sonetVTIntervalNumber}": {
      "get": {
        "summary": "Get sonetVTIntervalEntry entry",
        "description": "Retrieve specific sonetVTIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetVTIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetVTIntervalNumber": -2147483648,
                    "sonetVTIntervalESs": "example-string",
                    "sonetVTIntervalSESs": "example-string",
                    "sonetVTIntervalCVs": "example-string",
                    "sonetVTIntervalUASs": "example-string",
                    "sonetVTIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTIntervalEntry-2"
      },
      "x-yang-path": "/sonetVTIntervalTable/sonetVTIntervalEntry={ifIndex sonetVTIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetVTIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndVTIntervalTable/sonetFarEndVTIntervalEntry={ifIndex},{sonetFarEndVTIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndVTIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndVTIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndVTIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndVTIntervalNumber": -2147483648,
                    "sonetFarEndVTIntervalESs": "example-string",
                    "sonetFarEndVTIntervalSESs": "example-string",
                    "sonetFarEndVTIntervalCVs": "example-string",
                    "sonetFarEndVTIntervalUASs": "example-string",
                    "sonetFarEndVTIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTIntervalEntry-2"
      },
      "x-yang-path": "/sonetFarEndVTIntervalTable/sonetFarEndVTIntervalEntry={ifIndex sonetFarEndVTIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndVTIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetSectionIntervalEntry={ifIndex},{sonetSectionIntervalNumber}": {
      "get": {
        "summary": "Get sonetSectionIntervalEntry entry",
        "description": "Retrieve specific sonetSectionIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetSectionIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetSectionIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetSectionIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetSectionIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetSectionIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetSectionIntervalNumber": -2147483648,
                    "sonetSectionIntervalESs": "example-string",
                    "sonetSectionIntervalSESs": "example-string",
                    "sonetSectionIntervalSEFSs": "example-string",
                    "sonetSectionIntervalCVs": "example-string",
                    "sonetSectionIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetSectionIntervalEntry-4"
      },
      "x-yang-path": "/sonetSectionIntervalEntry={ifIndex sonetSectionIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetSectionIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetLineIntervalEntry={ifIndex},{sonetLineIntervalNumber}": {
      "get": {
        "summary": "Get sonetLineIntervalEntry entry",
        "description": "Retrieve specific sonetLineIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetLineIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetLineIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetLineIntervalNumber": -2147483648,
                    "sonetLineIntervalESs": "example-string",
                    "sonetLineIntervalSESs": "example-string",
                    "sonetLineIntervalCVs": "example-string",
                    "sonetLineIntervalUASs": "example-string",
                    "sonetLineIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetLineIntervalEntry-4"
      },
      "x-yang-path": "/sonetLineIntervalEntry={ifIndex sonetLineIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetLineIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndLineIntervalEntry={ifIndex},{sonetFarEndLineIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndLineIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndLineIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndLineIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndLineIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndLineIntervalNumber": -2147483648,
                    "sonetFarEndLineIntervalESs": "example-string",
                    "sonetFarEndLineIntervalSESs": "example-string",
                    "sonetFarEndLineIntervalCVs": "example-string",
                    "sonetFarEndLineIntervalUASs": "example-string",
                    "sonetFarEndLineIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndLineIntervalEntry-4"
      },
      "x-yang-path": "/sonetFarEndLineIntervalEntry={ifIndex sonetFarEndLineIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndLineIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetPathIntervalEntry={ifIndex},{sonetPathIntervalNumber}": {
      "get": {
        "summary": "Get sonetPathIntervalEntry entry",
        "description": "Retrieve specific sonetPathIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetPathIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetPathIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetPathIntervalNumber": -2147483648,
                    "sonetPathIntervalESs": "example-string",
                    "sonetPathIntervalSESs": "example-string",
                    "sonetPathIntervalCVs": "example-string",
                    "sonetPathIntervalUASs": "example-string",
                    "sonetPathIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetPathIntervalEntry-4"
      },
      "x-yang-path": "/sonetPathIntervalEntry={ifIndex sonetPathIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetPathIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndPathIntervalEntry={ifIndex},{sonetFarEndPathIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndPathIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndPathIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndPathIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndPathIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndPathIntervalNumber": -2147483648,
                    "sonetFarEndPathIntervalESs": "example-string",
                    "sonetFarEndPathIntervalSESs": "example-string",
                    "sonetFarEndPathIntervalCVs": "example-string",
                    "sonetFarEndPathIntervalUASs": "example-string",
                    "sonetFarEndPathIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndPathIntervalEntry-4"
      },
      "x-yang-path": "/sonetFarEndPathIntervalEntry={ifIndex sonetFarEndPathIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndPathIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetVTIntervalEntry={ifIndex},{sonetVTIntervalNumber}": {
      "get": {
        "summary": "Get sonetVTIntervalEntry entry",
        "description": "Retrieve specific sonetVTIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetVTIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetVTIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetVTIntervalNumber": -2147483648,
                    "sonetVTIntervalESs": "example-string",
                    "sonetVTIntervalSESs": "example-string",
                    "sonetVTIntervalCVs": "example-string",
                    "sonetVTIntervalUASs": "example-string",
                    "sonetVTIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetVTIntervalEntry-4"
      },
      "x-yang-path": "/sonetVTIntervalEntry={ifIndex sonetVTIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetVTIntervalNumber"
      ]
    },
    "/data/SONET-MIB:sonetFarEndVTIntervalEntry={ifIndex},{sonetFarEndVTIntervalNumber}": {
      "get": {
        "summary": "Get sonetFarEndVTIntervalEntry entry",
        "description": "Retrieve specific sonetFarEndVTIntervalEntry entry by key from MIB",
        "tags": [
          "SONET-MIB"
        ],
        "parameters": [
          {
            "name": "ifIndex",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "sonetFarEndVTIntervalNumber",
            "in": "path",
            "required": true,
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "Accept",
            "in": "header",
            "required": false,
            "description": "RESTCONF response media type (RFC 8040)",
            "schema": {
              "type": "string",
              "default": "application/yang-data+json",
              "enum": [
                "application/yang-data+json",
                "application/yang-data+xml"
              ]
            }
          },
          {
            "name": "depth",
            "in": "query",
            "required": false,
            "description": "Limit the depth of returned sub-tree data (RFC 8040 Section 4.8.2). Use 'unbounded' for full depth.",
            "schema": {
              "type": "string",
              "default": "unbounded"
            }
          },
          {
            "name": "fields",
            "in": "query",
            "required": false,
            "description": "Select specific fields to return (RFC 8040 Section 4.8.3). Example: fields=name;status",
            "schema": {
              "type": "string"
            }
          },
          {
            "name": "content",
            "in": "query",
            "required": false,
            "description": "Filter by config state: 'config' (config true only), 'nonconfig' (config false only), or 'all'.",
            "schema": {
              "type": "string",
              "enum": [
                "config",
                "nonconfig",
                "all"
              ],
              "default": "all"
            }
          }
        ],
        "responses": {
          "200": {
            "description": "Success",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref"
                    },
                    "sonetFarEndVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647
                    },
                    "sonetFarEndVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount"
                    },
                    "sonetFarEndVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid."
                    }
                  }
                },
                "example": {
                  "SONET-MIB:sonetFarEndVTIntervalEntry": {
                    "ifIndex": "example-string",
                    "sonetFarEndVTIntervalNumber": -2147483648,
                    "sonetFarEndVTIntervalESs": "example-string",
                    "sonetFarEndVTIntervalSESs": "example-string",
                    "sonetFarEndVTIntervalCVs": "example-string",
                    "sonetFarEndVTIntervalUASs": "example-string",
                    "sonetFarEndVTIntervalValidData": true
                  }
                }
              }
            }
          },
          "403": {
            "description": "Forbidden — insufficient access rights (NACM)",
            "content": {
              "application/yang-data+json": {
                "schema": {
                  "$ref": "#/components/schemas/restconf-error"
                }
              }
            }
          }
        },
        "operationId": "get-sonetFarEndVTIntervalEntry-4"
      },
      "x-yang-path": "/sonetFarEndVTIntervalEntry={ifIndex sonetFarEndVTIntervalNumber}",
      "x-restconf-kind": "list-instance",
      "x-list-keys": [
        "ifIndex sonetFarEndVTIntervalNumber"
      ]
    }
  },
  "components": {
    "schemas": {
      "SONET-MIB_SONET-MIB": {
        "type": "object",
        "description": "SONET-MIB",
        "properties": {
          "sonetMediumEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Medium table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetMediumType": {
                  "type": "string",
                  "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface.",
                  "readOnly": true
                },
                "sonetMediumTimeElapsed": {
                  "type": "integer",
                  "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetMediumValidIntervals": {
                  "type": "integer",
                  "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetMediumLineCoding": {
                  "type": "string",
                  "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals.",
                  "readOnly": true
                },
                "sonetMediumLineType": {
                  "type": "string",
                  "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values.",
                  "readOnly": true
                },
                "sonetMediumCircuitIdentifier": {
                  "type": "string",
                  "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                  "x-yang-type": "snmpv2-tc:DisplayString",
                  "readOnly": true
                },
                "sonetMediumInvalidIntervals": {
                  "type": "integer",
                  "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetMediumLoopbackConfig": {
                  "type": "string",
                  "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetSectionCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Section Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetSectionCurrentStatus": {
                  "type": "integer",
                  "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetSectionCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetSectionCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetSectionCurrentSEFSs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetSectionCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetSectionIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Section Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetSectionIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetSectionIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetSectionIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetSectionIntervalSEFSs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetSectionIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetSectionIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetLineCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Line Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetLineCurrentStatus": {
                  "type": "integer",
                  "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetLineCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetLineCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetLineCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetLineCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetLineIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Line Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetLineIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetLineIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetLineIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetLineIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetLineIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetLineIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndLineCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far End Line Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndLineCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndLineCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndLineCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndLineCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndLineIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndLineIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetFarEndLineIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndLineIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndLineIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndLineIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndLineIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetPathCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Path Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetPathCurrentWidth": {
                  "type": "string",
                  "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256.",
                  "readOnly": true
                },
                "sonetPathCurrentStatus": {
                  "type": "integer",
                  "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetPathCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetPathCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetPathCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetPathCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetPathIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Path Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetPathIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetPathIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetPathIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetPathIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetPathIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetPathIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndPathCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far End Path Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndPathCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndPathCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndPathCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndPathCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndPathIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndPathIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetFarEndPathIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndPathIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndPathIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndPathIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndPathIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetVTCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH VT Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetVTCurrentWidth": {
                  "type": "string",
                  "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c.",
                  "readOnly": true
                },
                "sonetVTCurrentStatus": {
                  "type": "integer",
                  "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetVTCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetVTCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetVTCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetVTCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetVTIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH VT Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetVTIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetVTIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetVTIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetVTIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetVTIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetVTIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndVTCurrentEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far End VT Current table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndVTCurrentESs": {
                  "type": "string",
                  "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndVTCurrentSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndVTCurrentCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                },
                "sonetFarEndVTCurrentUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                  "x-yang-type": "perfhist-tc:PerfCurrentCount",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetFarEndVTIntervalEntry": {
            "type": "array",
            "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
            "items": {
              "type": "object",
              "properties": {
                "ifIndex": {
                  "type": "string",
                  "description": "ifIndex",
                  "x-yang-type": "leafref",
                  "readOnly": true
                },
                "sonetFarEndVTIntervalNumber": {
                  "type": "integer",
                  "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                  "minimum": -2147483648,
                  "maximum": 2147483647,
                  "readOnly": true
                },
                "sonetFarEndVTIntervalESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndVTIntervalSESs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndVTIntervalCVs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndVTIntervalUASs": {
                  "type": "string",
                  "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                  "x-yang-type": "perfhist-tc:PerfIntervalCount",
                  "readOnly": true
                },
                "sonetFarEndVTIntervalValidData": {
                  "type": "boolean",
                  "description": "This variable indicates if the data for this\n            interval is valid.",
                  "readOnly": true
                }
              }
            },
            "readOnly": true
          },
          "sonetMedium": {
            "type": "object",
            "description": "sonetMedium",
            "properties": {
              "sonetSESthresholdSet": {
                "type": "string",
                "description": "An enumerated integer indicating which\n          recognized set of SES thresholds that\n          the agent uses for determining severely\n          errored seconds and unavailable time.\n          \n          other(1)\n            None of the following.\n          \n          bellcore1991(2)\n            Bellcore TR-NWT-000253, 1991 [TR253], or\n            ANSI T1M1.3/93-005R2, 1993 [T1M1.3].\n            See also Appendix B.\n          \n          ansi1993(3)\n            ANSI T1.231, 1993 [T1.231a], or\n            Bellcore GR-253-CORE, Issue 2, 1995 [GR253]\n          \n          itu1995(4)\n            ITU Recommendation G.826, 1995 [G.826]\n          \n          ansi1997(5)\n            ANSI T1.231, 1997 [T1.231b]\n          \n          If a manager changes the value of this\n          object then the SES statistics collected\n          prior to this change must be invalidated.",
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetMediumTable": {
            "type": "object",
            "description": "The SONET/SDH Medium table.",
            "properties": {
              "sonetMediumEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Medium table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetMediumType": {
                      "type": "string",
                      "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface.",
                      "readOnly": true
                    },
                    "sonetMediumTimeElapsed": {
                      "type": "integer",
                      "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetMediumValidIntervals": {
                      "type": "integer",
                      "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetMediumLineCoding": {
                      "type": "string",
                      "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals.",
                      "readOnly": true
                    },
                    "sonetMediumLineType": {
                      "type": "string",
                      "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values.",
                      "readOnly": true
                    },
                    "sonetMediumCircuitIdentifier": {
                      "type": "string",
                      "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
                      "x-yang-type": "snmpv2-tc:DisplayString",
                      "readOnly": true
                    },
                    "sonetMediumInvalidIntervals": {
                      "type": "integer",
                      "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetMediumLoopbackConfig": {
                      "type": "string",
                      "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetSectionCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Section Current table.",
            "properties": {
              "sonetSectionCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Section Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetSectionCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetSectionCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetSectionCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetSectionCurrentSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetSectionCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetSectionIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Section Interval table.",
            "properties": {
              "sonetSectionIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Section Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetSectionIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetSectionIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetSectionIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetSectionIntervalSEFSs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetSectionIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetSectionIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetLineCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Line Current table.",
            "properties": {
              "sonetLineCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Line Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetLineCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetLineIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Line Interval table.",
            "properties": {
              "sonetLineIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Line Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndLineCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Far End Line Current table.",
            "properties": {
              "sonetFarEndLineCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far End Line Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndLineCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndLineIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Far End Line Interval table.",
            "properties": {
              "sonetFarEndLineIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndLineIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetPathCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Path Current table.",
            "properties": {
              "sonetPathCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Path Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetPathCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256.",
                      "readOnly": true
                    },
                    "sonetPathCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetPathIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Path Interval table.",
            "properties": {
              "sonetPathIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Path Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndPathCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Far End Path Current table.",
            "properties": {
              "sonetFarEndPathCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far End Path Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndPathCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndPathIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Far End Path Interval table.",
            "properties": {
              "sonetFarEndPathIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndPathIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetVTCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH VT Current table.",
            "properties": {
              "sonetVTCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH VT Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetVTCurrentWidth": {
                      "type": "string",
                      "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c.",
                      "readOnly": true
                    },
                    "sonetVTCurrentStatus": {
                      "type": "integer",
                      "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetVTIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH VT Interval table.",
            "properties": {
              "sonetVTIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH VT Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndVTCurrentTable": {
            "type": "object",
            "description": "The SONET/SDH Far End VT Current table.",
            "properties": {
              "sonetFarEndVTCurrentEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far End VT Current table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndVTCurrentESs": {
                      "type": "string",
                      "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTCurrentSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTCurrentCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTCurrentUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
                      "x-yang-type": "perfhist-tc:PerfCurrentCount",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          },
          "sonetFarEndVTIntervalTable": {
            "type": "object",
            "description": "The SONET/SDH Far End VT Interval table.",
            "properties": {
              "sonetFarEndVTIntervalEntry": {
                "type": "array",
                "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
                "items": {
                  "type": "object",
                  "properties": {
                    "ifIndex": {
                      "type": "string",
                      "description": "ifIndex",
                      "x-yang-type": "leafref",
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalNumber": {
                      "type": "integer",
                      "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
                      "minimum": -2147483648,
                      "maximum": 2147483647,
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalSESs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalCVs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalUASs": {
                      "type": "string",
                      "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
                      "x-yang-type": "perfhist-tc:PerfIntervalCount",
                      "readOnly": true
                    },
                    "sonetFarEndVTIntervalValidData": {
                      "type": "boolean",
                      "description": "This variable indicates if the data for this\n            interval is valid.",
                      "readOnly": true
                    }
                  }
                },
                "readOnly": true
              }
            },
            "readOnly": true
          }
        }
      },
      "SONET-MIB_sonetMediumEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Medium table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetMediumType": {
              "type": "string",
              "description": "This variable identifies whether a SONET\n            or a SDH signal is used across this interface.",
              "readOnly": true
            },
            "sonetMediumTimeElapsed": {
              "type": "integer",
              "description": "The number of seconds, including partial seconds,\n            that have elapsed since the beginning of the current\n            measurement period. If, for some reason, such as an\n            adjustment in the system's time-of-day clock, the\n            current interval exceeds the maximum value, the\n            agent will return the maximum value.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetMediumValidIntervals": {
              "type": "integer",
              "description": "The number of previous 15-minute intervals\n            for which data was collected.\n            A SONET/SDH interface must be capable\n            of supporting at least n intervals.\n            The minimum value of n is 4.\n            The default of n is 32.\n            The maximum value of n is 96.\n            The value will be <n> unless the measurement was\n            (re-)started within the last (<n>*15) minutes, in which\n            case the value will be the number of complete 15\n            minute intervals for which the agent has at least\n            some data. In certain cases (e.g., in the case\n            where the agent is a proxy) it is possible that some\n            intervals are unavailable.  In this case, this\n            interval is the maximum interval number for\n            which data is available.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetMediumLineCoding": {
              "type": "string",
              "description": "This variable describes the line coding for\n            this interface. The B3ZS and CMI are used for\n            electrical SONET/SDH signals (STS-1 and STS-3).\n            The Non-Return to Zero (NRZ) and the Return\n            to Zero are used for optical SONET/SDH signals.",
              "readOnly": true
            },
            "sonetMediumLineType": {
              "type": "string",
              "description": "This variable describes the line type for\n            this interface. The line types are\n            Short and Long Range\n            Single Mode fiber or Multi-Mode fiber interfaces,\n            and coax and UTP for electrical interfaces.  The\n            value sonetOther should be used when the Line Type is\n            not one of the listed values.",
              "readOnly": true
            },
            "sonetMediumCircuitIdentifier": {
              "type": "string",
              "description": "This variable contains the transmission\n            vendor's circuit identifier, for the\n            purpose of facilitating troubleshooting.\n            Note that the circuit identifier, if available,\n            is also represented by ifPhysAddress.",
              "x-yang-type": "snmpv2-tc:DisplayString",
              "readOnly": true
            },
            "sonetMediumInvalidIntervals": {
              "type": "integer",
              "description": "The number of intervals in the range from\n            0 to sonetMediumValidIntervals for which no\n            data is available. This object will typically\n            be zero except in cases where the data for some\n            intervals are not available (e.g., in proxy\n            situations).",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetMediumLoopbackConfig": {
              "type": "string",
              "description": "The current loopback state of the SONET/SDH interface.  The\n            values mean:\n            \n              sonetNoLoop\n                 Not in the loopback state. A device that is not\n                 capable of performing a loopback on this interface\n                 shall always return this value.\n            \n              sonetFacilityLoop\n                 The received signal at this interface is looped back\n                 out through the corresponding transmitter in the return\n                 direction.\n            \n              sonetTerminalLoop\n                 The signal that is about to be transmitted is connected\n                 to the associated incoming receiver.\n            \n              sonetOtherLoop\n                 Loopbacks that are not defined here.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetSectionCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Section Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetSectionCurrentStatus": {
              "type": "integer",
              "description": "This variable indicates the\n            status of the interface.\n            The sonetSectionCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetSectionNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n                  1   sonetSectionNoDefect\n                  2   sonetSectionLOS\n                  4   sonetSectionLOF",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetSectionCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Section in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetSectionCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in the current 15\n            minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetSectionCurrentSEFSs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in the current\n            15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetSectionCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetSectionIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Section Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetSectionIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetSectionIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetSectionIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetSectionIntervalSEFSs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Framing Seconds\n            encountered by a SONET/SDH Section in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetSectionIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Section in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetSectionIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetLineCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Line Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetLineCurrentStatus": {
              "type": "integer",
              "description": "This variable indicates the\n            status of the interface.\n            The sonetLineCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetLineNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n             1   sonetLineNoDefect\n             2   sonetLineAIS\n             4   sonetLineRDI",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetLineCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Line in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetLineCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetLineCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetLineCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a SONET/SDH Line in the current 15\n            minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetLineIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Line Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetLineIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetLineIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetLineIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetLineIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Line in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetLineIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the\n            number of Unavailable Seconds\n            encountered by a SONET/SDH Line in\n            a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetLineIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndLineCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far End Line Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndLineCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndLineCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Medium/Section/Line\n            interface in the current 15 minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndLineCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndLineCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Medium/Section/Line\n            interface in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndLineIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far\n          End Line Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndLineIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetFarEndLineIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndLineIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndLineIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndLineIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Line\n            interface in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndLineIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetPathCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Path Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetPathCurrentWidth": {
              "type": "string",
              "description": "A value that indicates the type of the SONET/SDH\n            Path.  For SONET, the assigned types are\n            the STS-Nc SPEs, where N = 1, 3, 12, 24, 48, 192 and 768.\n            STS-1 is equal to 51.84 Mbps.  For SDH, the assigned\n            types are the STM-Nc VCs, where N = 1, 4, 16, 64 and 256.",
              "readOnly": true
            },
            "sonetPathCurrentStatus": {
              "type": "integer",
              "description": "This variable indicates the\n            status of the interface.\n            The sonetPathCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            simultaneously.\n            The sonetPathNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetPathNoDefect\n               2   sonetPathSTSLOP\n               4   sonetPathSTSAIS\n               8   sonetPathSTSRDI\n              16   sonetPathUnequipped\n              32   sonetPathSignalLabelMismatch",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetPathCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            Path in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetPathCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in the current 15\n            minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetPathCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetPathCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in the current\n            15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetPathIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Path Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetPathIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetPathIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetPathIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH Path in\n            a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetPathIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH Path in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetPathIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a Path in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetPathIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndPathCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far End Path Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndPathCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndPathCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path\n            interface in the current 15 minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndPathCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndPathCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndPathIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far\n          End Path Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndPathIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetFarEndPathIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH Path interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndPathIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndPathIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH Path interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndPathIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH Path interface in\n            a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndPathIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetVTCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH VT Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetVTCurrentWidth": {
              "type": "string",
              "description": "A value that indicates the type of the SONET\n            VT and SDH VC.  Assigned widths are\n            VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c.",
              "readOnly": true
            },
            "sonetVTCurrentStatus": {
              "type": "integer",
              "description": "This variable indicates the\n            status of the interface.\n            The sonetVTCurrentStatus\n            is a bit map represented\n            as a sum, therefore,\n            it can represent multiple defects\n            and failures\n            simultaneously.\n            The sonetVTNoDefect should be\n            set if and only if\n            no other flag is set.\n            \n            The various bit positions are:\n               1   sonetVTNoDefect\n               2   sonetVTLOP\n               4   sonetVTPathAIS\n               8   sonetVTPathRDI\n              16   sonetVTPathRFI\n              32   sonetVTUnequipped\n              64   sonetVTSignalLabelMismatch",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetVTCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Errored\n            Seconds encountered by a SONET/SDH\n            VT in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetVTCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT in the current 15 minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetVTCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetVTCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in the current\n            15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetVTIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH VT Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetVTIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetVTIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Errored Seconds encountered\n            by a SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetVTIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Severely Errored Seconds\n            encountered by a SONET/SDH VT\n            in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetVTIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of Coding\n            Violations encountered by a\n            SONET/SDH VT in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetVTIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Unavailable Seconds\n            encountered by a VT in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetVTIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndVTCurrentEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far End VT Current table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndVTCurrentESs": {
              "type": "string",
              "description": "The counter associated with the number of Far\n            End Errored Seconds encountered by a SONET/SDH\n            interface in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndVTCurrentSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in the current 15 minute\n            interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndVTCurrentCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            },
            "sonetFarEndVTCurrentUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface\n            in the current 15 minute interval.",
              "x-yang-type": "perfhist-tc:PerfCurrentCount",
              "readOnly": true
            }
          }
        }
      },
      "SONET-MIB_sonetFarEndVTIntervalEntry": {
        "type": "array",
        "description": "An entry in the SONET/SDH Far\n          End VT Interval table.",
        "items": {
          "type": "object",
          "properties": {
            "ifIndex": {
              "type": "string",
              "description": "ifIndex",
              "x-yang-type": "leafref",
              "readOnly": true
            },
            "sonetFarEndVTIntervalNumber": {
              "type": "integer",
              "description": "A number between 1 and 96, which identifies the\n            interval for which the set of statistics is available.\n            The interval identified by 1 is the most recently\n            completed 15 minute interval,\n            and the interval identified\n            by N is the interval immediately preceding the\n            one identified\n            by N-1.",
              "minimum": -2147483648,
              "maximum": 2147483647,
              "readOnly": true
            },
            "sonetFarEndVTIntervalESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Errored Seconds encountered\n            by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndVTIntervalSESs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Severely Errored Seconds\n            encountered by a SONET/SDH VT interface\n            in a particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndVTIntervalCVs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Coding Violations reported via\n            the far end block error count\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndVTIntervalUASs": {
              "type": "string",
              "description": "The counter associated with the number of\n            Far End Unavailable Seconds\n            encountered by a\n            SONET/SDH VT interface in a\n            particular 15-minute interval\n            in the past 24 hours.",
              "x-yang-type": "perfhist-tc:PerfIntervalCount",
              "readOnly": true
            },
            "sonetFarEndVTIntervalValidData": {
              "type": "boolean",
              "description": "This variable indicates if the data for this\n            interval is valid.",
              "readOnly": true
            }
          }
        }
      },
      "restconf-error": {
        "type": "object",
        "description": "Standard RESTCONF error response (RFC 8040 Section 7.1)",
        "properties": {
          "ietf-restconf:errors": {
            "type": "object",
            "properties": {
              "error": {
                "type": "array",
                "items": {
                  "type": "object",
                  "properties": {
                    "error-type": {
                      "type": "string",
                      "enum": [
                        "transport",
                        "rpc",
                        "protocol",
                        "application"
                      ],
                      "description": "Layer where the error occurred"
                    },
                    "error-tag": {
                      "type": "string",
                      "description": "Enumerated error tag (e.g. invalid-value, data-missing, access-denied)"
                    },
                    "error-severity": {
                      "type": "string",
                      "enum": [
                        "error",
                        "warning"
                      ],
                      "description": "Error severity"
                    },
                    "error-app-tag": {
                      "type": "string",
                      "description": "Application-specific error tag"
                    },
                    "error-path": {
                      "type": "string",
                      "description": "YANG instance-identifier of the error node"
                    },
                    "error-message": {
                      "type": "string",
                      "description": "Human-readable error description"
                    }
                  },
                  "required": [
                    "error-type",
                    "error-tag"
                  ]
                }
              }
            }
          }
        },
        "example": {
          "ietf-restconf:errors": {
            "error": [
              {
                "error-type": "protocol",
                "error-tag": "invalid-value",
                "error-severity": "error",
                "error-message": "Invalid input parameter"
              }
            ]
          }
        }
      }
    },
    "securitySchemes": {
      "basicAuth": {
        "type": "http",
        "scheme": "basic"
      }
    }
  },
  "security": [
    {
      "basicAuth": []
    }
  ],
  "tags": [
    {
      "name": "SONET-MIB",
      "description": "MIB operations for SONET-MIB"
    }
  ],
  "externalDocs": {
    "description": "Cisco SNMP Object Navigator",
    "url": "https://snmp.cloudapps.cisco.com/Support/IOS/do/BrowseMIB.do"
  }
}
